The larger Schwing Stetter plants mix with two horizontal shafts in one trough. The design mixes fast, wears in few places, and can restart with a full load. This is how it works, how a new one is commissioned, and what its common symptoms mean.
How it mixes
Each shaft is a hexagonal bar with mixing arms set around it in a spiral. As the shafts turn, the arms push material along the shaft and around it at once, so it travels a three-dimensional path. Where the two mixing circles cross, material from both sides meets, and that overlap is what brings the mix together so quickly.
Built to wear in few places
- Only about 30% of each mixing tool's rotation is exposed to wear on the trough floor.
- Only three to four rows of bottom tiles take the wear, and the tiles are identical, so they are simple to replace.
- The mixing arms are modular special castings. One arm can be replaced without the rest.
- The shaft bearings are separate from the shaft seals. If a seal fails, the bearing behind it is not damaged, and the seal is easy to reach.
The drive
- Worm gear reducers with an efficiency above 92%. They absorb the shock of sudden feeding or a restart under full load.
- A synchronous coupling between the two gear units keeps the shafts in step. It is elastic and maintenance free.
- A torque support lets the drive hang freely, keeps the coupling aligned and takes load off the gearbox bearings.
- Central grease lubrication feeds the four shaft seals while the mixer runs.
The discharge door
The door is worked by two or four pneumatic cylinders, depending on mixer size, with hydraulic cylinders as an option. It opens in stages, so a transit mixer can be fed at the rate it can take. The standard door has a half-open position; the large door has two intermediate positions.
Commissioning a new mixer
- Check the installation. Casing level, feed and discharge devices fitted, limit switches fitted on the maintenance doors, guards on all rotating parts.
- Check the mixer itself. About 3 mm between the mixing tools and the trough, shafts turning freely, V-belt tension, gearbox oil level, no foreign material in the trough.
- Run it empty for 20 to 30 minutes. Listen for abnormal noise and test the emergency stop and the limit switches. On a star-delta drive, the switch from star to delta takes 2.5 to 3 seconds.
- Check the door. Air pressure at 8 bar, cylinders cycled several times, limit switches reset if needed, grease showing at the axial face seals.
- Break it in. Two batches at half the nominal filling and a third at nominal filling, 60 seconds each.
- Go gently for the first ten mixes. Use fluid concrete with a maximum particle size of 4 mm.
Feeding and running
- Feed in a fixed, timed order. Aggregates first, water one to two seconds later, and the binder once 80 to 90% of the aggregate is in.
- Keep mixing time short. Mixing for more than two minutes increases wear and heats the drive.
- Watch the gear unit temperature. In continuous work it runs 25 to 45°C above ambient and must not exceed 90°C.
- If the mixer stops with a load in it, open the discharge door and empty the trough. In a power failure the door can still be opened with the emergency controls on its solenoid valves, using the air left in the system.
What the symptoms mean
| Symptom | Probable cause | Action |
|---|---|---|
| Mixer does not start when empty, on a two-motor drive | Motors turning in opposite directions | Reverse one motor and confirm the shafts rotate correctly |
| Mixer stops under load | Loose V-belts, low oil in the hydraulic coupling, or an electrical fault | Retension the belts, check the oil filling, check supply, fuses and voltage |
| Discharge door does not open | Air supply below 8 bar, or stones jammed at the door | Raise the line pressure; free the door |
| Deposits on shafts, tools and cover | Cement called too early or water too late | Correct the feeding sequence |
| Loud mixing noise | Blade gap too large | Readjust the lateral and central blades |
| Excessive tool wear | Blade gap or door sealing gap too large, or mixing time too long | Readjust the blades, reset the sealing ledges, shorten the mixing time |
| Cement slurry leaking at the shaft seal | Axial face seal damaged by lack of lubrication | Replace the axial face seal |
Lubrication
The worm gear reducers take gear oil VG 460: 70 liters on the mixer in the manufacturer's list, first changed at 500 hours and then every 2,000 hours. EP 2 grease is used on all bearings, seals and grease nipples. After the mixer has been cleaned, grease the shaft seals by hand. The rest is in our lubrication guide.
Running a twin-shaft plant?